Abstract:
Five components in the impurity profile of tinidazole glucose injection were detected and identified by UPLC-Q Exactive quadrupole-electrostatic field orbitrap high resolution mass spectrometry, in combination with retention time references, organic reaction mechanisms and UV spectral analysis. They are 2-methyl-5-nitroimidazole (impurity
1), 5-hydroxymethylfurfural (impurity
2), 1-(2-(ethylsulfonyl)ethyl)-2-methyl-4-nitro-1
H-Imidazole (impurity
5), 1-(2-(ethylthio)ethyl)-2-methyl-5-nitro-1
H-imidazole (impurity
6) and 1,4-di-
N-oxo-2-methyl-5-nitro-1
H-imidazole (impurity
8) respectively, of which impurities
6 and
8 are identified for the first time. These results and detection methods are useful for monitoring the manufacturing process and quality control of tinidazole and glucose injection solution.