Abstract:
AIM To establish a reverse-phase high performance liquid chromatographic method for the determination of pravastatin in rat liver. METHODS An aliquot of 5 g liver homogenates, spiked with triamcinolone acetonide (internal standard), was extracted by solid-phase extraction with Bond Elut C
18 columns. Chromatography was performed using a C
18 reverse-phase column with mobile phase of Na
2HPO
4 buffer sdution (0.035 mmol·L
-1, pH 3.0)-acetonitrile (155∶42). RESULTS The linear equation was
Y=0.1843X-4.238×10
-3 (
γ=0.9934) in the range of 0.05-10 μg·g
-1 liver. The limit of detection for pravastatin was 13 ng·mL
-1 (signal-to-noise ratio of 3), and the limit of quantification for pravastatin in liver homogenate was 50 ng·g
-1 liver (RSD<20%). The average extraction recovery of pravastatin from liver at different concentrations was 80.8%, and the average inter-day precision was 11%. This procedure was applied to assay pravastatin in rat liver which were collected from Lewis rats at different times after administration of pravastatin (ig 20 mg·kg
-1). CONCLUSION The method was sensitive and is feasible for the pharmacokinetic and distribution study of pravastatin.