WANG Jing-jing, DU Wei-feng, WEI Xing-hong, XIE Zi-li, CHENG Jie. Identification of impurity profile in tinidazole glucose injection by UPLC-MSJ. Acta Pharmaceutica Sinica, 2019,54(9): 1655-1660. doi: 10.16438/j.0513-4870.2019-0278
Citation: WANG Jing-jing, DU Wei-feng, WEI Xing-hong, XIE Zi-li, CHENG Jie. Identification of impurity profile in tinidazole glucose injection by UPLC-MSJ. Acta Pharmaceutica Sinica, 2019,54(9): 1655-1660. doi: 10.16438/j.0513-4870.2019-0278

Identification of impurity profile in tinidazole glucose injection by UPLC-MS

  • Five components in the impurity profile of tinidazole glucose injection were detected and identified by UPLC-Q Exactive quadrupole-electrostatic field orbitrap high resolution mass spectrometry, in combination with retention time references, organic reaction mechanisms and UV spectral analysis. They are 2-methyl-5-nitroimidazole (impurity 1), 5-hydroxymethylfurfural (impurity 2), 1-(2-(ethylsulfonyl)ethyl)-2-methyl-4-nitro-1H-Imidazole (impurity 5), 1-(2-(ethylthio)ethyl)-2-methyl-5-nitro-1H-imidazole (impurity 6) and 1,4-di-N-oxo-2-methyl-5-nitro-1H-imidazole (impurity 8) respectively, of which impurities 6 and 8 are identified for the first time. These results and detection methods are useful for monitoring the manufacturing process and quality control of tinidazole and glucose injection solution.