Analysis of polymer impurities in ceftazidime raw materials and preparations
-
Abstract
To establish a method for the determination of polymer impurities in ceftazidime raw materials and preparations, a ceftazidime degradation solution containing polymer impurities was prepared by forced polymerization. Polymer impurities in the degradation solution were separated and identified by high performance gel chromatography and the column switching-LC-MSn method. A new RP-HPLC method for ceftazidime polymer was established and validated with a Phenomenex Gemini-C18 column using a mobile phase gradient elution of 0.02 mol·L-1 phosphate buffer, methanol and acetonitrile. The results showed that when using this high performance gel chromatography method some small molecular weight impurities were co-eluted with the polymers, resulting in a poor specificity and poor quantitative accuracy. But when using the RP-HPLC method, four polymer impurities were detected in the 25-45 min time range with good specificity, sensitivity and robustness, including two ceftazidime dimers, trimers, and derivatives. Therefore, the described RP-HPLC method is suitable for the quality control of polymer impurities in ceftazidime, and ceftazidime degradation solution can be used as suitable solution for analysis of ceftazidime polymers.
-
-