ZHU Shi-Min, JIANG Jian-Hua , PENG Ci-Zhen, . STUDY ON FILCILIN ION SELECTIVE ELECTRODEJ. Acta Pharmaceutica Sinica, 1986, 21(3): 198-203.
Citation: ZHU Shi-Min, JIANG Jian-Hua , PENG Ci-Zhen, . STUDY ON FILCILIN ION SELECTIVE ELECTRODEJ. Acta Pharmaceutica Sinica, 1986, 21(3): 198-203.

STUDY ON FILCILIN ION SELECTIVE ELECTRODE

  • The liquid-membrane and PVC membrane ion-selective electrodes for filcilin were studied. They are based on the use of tetraphenylborate-filcilin ion pair complex as the active material. The PVC membrane electrode showed Nernstian response in 10-2~10-5M filcilin solution over a pH range of 2.3~6.7 with cationic slope of 58 mV/pC. The electrode showed rapid response, good reproducibility and precision. Using direct potentiometric determination, the recovery of pure filcilin was 99.7% and the standard deviation was ±1.8%, the standard deviation of actual determination of samples was ±0.43. The selectivity coefficient of 24 substances was tested, most of them did not interfere.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return