ZHANG Hui, YU Chen, HONG You-Cai, JIANG Shan-Hao, SHEN Jing-Kang, ZHU Da-Yuan. DETERMINATION OF PALMATINE IN SERUM BY HPLC-FLUJ. Acta Pharmaceutica Sinica, 2000, 35(7): 518-520.
Citation: ZHANG Hui, YU Chen, HONG You-Cai, JIANG Shan-Hao, SHEN Jing-Kang, ZHU Da-Yuan. DETERMINATION OF PALMATINE IN SERUM BY HPLC-FLUJ. Acta Pharmaceutica Sinica, 2000, 35(7): 518-520.

DETERMINATION OF PALMATINE IN SERUM BY HPLC-FLU

  • AIM To develop a method for analysis of palmatine in serum by high performance liquid chromatography with fluorometric detector. METHODS Separation was obtained by using a LiChrosorb SI 60 column(4.0 mm×200 mm, 5 μm). The mobile phase consisted of a mixture of dichloromethane-methanol-diethyl amine-acetic acid(90∶9∶0.4∶0.5) and the flow rate was 1 mL.min-1. Excitation and emission wavelengths were set at 365 and 510 nm respectively. To 1.0 mL of serum containing palmatine was added 13-methylberberine (internal standard, IS), then extracted with 5.0 mL chloroform containing trichloroacetic acid. The organic phase was removed with nitrogen and the residue dissolved with 100 μL dichloromethane. After centrifugation, 20 μL of the lower layer was subjected to HPLC. RESULTS The retention times of palmatine and IS were 8.4 and 7.1 min respectively. In serum the detection limit of palmatine was 0.1 ng.mL-1. The extraction recoveries of palmatine and IS were over 85%. The relative standard deviations of within-day and between-day were 0.94%~1.85% and 0.10%~6.47% (n=6) respectively. CONCLUSION This method is sensitive, simple and fast, so it can fit the need of palmatine pharmacokinetic research preferably.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return