DETERMINATION OF FLUCONAZOLE BY DIRECT INJECTION OF PLASMA AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH COLUMN SWITCHING
-
Abstract
High performance liquid chromatography with colunm switching has been developed for the determination of fluconazole in plasma.The plasma samples were injected onto aprecolumn packed with LiChromprep RP2(25~40μm) after simple dilution with a solution of 0.2mol·L-1 High performance liquid chromatography with colunm switching has been developed for the determination of fluconazole in plasma.The plasma samples were injected onto a precolumn packed with LiChromprep RP2(25~40μm)after simple dilution with a solution of 0.2 mol·L-1 acetic acid.Distilled water was used to wash out protein and other polar components in plasma.After switching, the concentrated fluconazole was eluted in the back-flush mode onto a Shimpack CLC-ODS column with methanol-0.2 mol·L-1 ammonium acetate(pH 2.7)(50 :50 )as mobile phase.Purge solutions were used for clean-up and for regenerating the precolumn,The method showed a good precision and excellent recovery.The detection limit was 0.12μg·mL-1 plasma.The RSD's(intra-andinterday )were less than 6.3%. The method has been successfully used to determine bioavailability and pharmacokinetics of fluconazole in Chinese volunteers.
-
-